Project Description
Project Name | IBC Charging Arm |
---|---|
Industry | Pharmaceutical |
Project Requirements | Complete the design and manufacture of a bespoke solution to lift a pollybottle and split butterfly valve above an IBC using an existing lifting device to reduce heavy lifting when charging the IBC. |
Our Solution | We completed a survey of the existing IBC and lifting device. We then developed a concept design for review and client approval. Our team then developed the detailed design for manufacture and completed the fabrication and assembly of the arm and jig. Load testing and certification was performed, and quality documentation was provided to support the client’s change control process. |
We completed a survey of the existing IBC and lifting device. We then developed a concept design for review and client approval. Our team then developed the detailed design for manufacture and completed the fabrication and assembly of the arm and jig. Load testing and certification was performed, and quality documentation was provided to support the client’s change control process.